Look at the LED lamps on your pump control panel and select the matching state for each lamp below.
LAMP (LED) 1
LAMP (LED) 2
LAMP (LED) 3
Error Type Result (11 results)
| # | Error Case | Description / Cause | Solution |
|---|---|---|---|
| 1 | Starting up and priming |
Shown after the pump has been filled with water and plugged in, until the pump starts drawing water. |
|
| 2 | Normal operation |
Normal constant-pressure operation (the pump runs at the pressure set with the pressure knob on the control unit). |
|
| 3 | Full-load operation |
The motor is running at its maximum speed (full load). Water pressure is lower than the pressure set with the pressure knob. |
|
| 4 | Low outflow (under 4 L/min) or pump stopped |
Water outflow is low (under 4 litres per minute), or the pump has stopped after every outlet valve was closed. The pump runs for about 10 seconds and then stops. |
|
| 5 | Pump head temperature too high |
If the pump head gets so hot that it reaches 65 °C, the pump stops. Once the pump head cools below 50 °C, the pump restarts automatically. |
|
| 6 | Water shortage (initial) |
If the water supply runs out while the pump is running for about 10 minutes, the pump stops briefly (about 1–10 minutes) and then restarts automatically. |
|
| 7 | Water shortage (prolonged) |
After the initial water-shortage stop has repeated 5 times, the pump stops completely. To run the pump again once there is water, press Reset on the control unit. |
Make sure there is water, then press Reset on the control unit. |
| 8 | Overcurrent (Over Load) |
If the motor is badly overloaded, or a foreign object is caught in the impeller or the impeller locks so the motor cannot turn, the control unit stops the pump. To run the pump again after the repair, press Reset on the control unit. |
After the repair, press Reset on the control unit. |
| 9 | No water in the storage tank or sump (float switch connected) |
Applies when the float-switch terminals are in use (the factory normally shorts them) to control the water level in the tank or sump before the pump. If the level falls below the set point the pump stops, and it restarts automatically once the level rises again. |
|
| 10 | Supply voltage too low |
If the supply voltage drops below 150 V the pump stops, and it returns to normal operation when the voltage recovers. If the voltage stays low for a long time, the pump stops completely until Reset is pressed on the control unit. |
Once the supply voltage is back to normal, press Reset on the control unit. |
| 11 | Control unit short circuit and other faults |
If the lamps blink in a pattern that matches none of the above, press Reset on the control unit. If the pump still does not work, contact the service centre on 0-2763-7000 press 6, or the hotline 1325. |
Press Reset on the control unit. If the pump still does not work, call 0-2763-7000 (press 6) or the hotline 1325. |