Skip to main content

Error Code Lookup

Find the meaning and solution for error codes displayed on your Mitsubishi Electric products.

2

Select Jet Towel Model

3

Enter Error Information

LAMP STATES

Power lamp

Heater/Check Lamp

4

Error Pattern Results (2 results)

Error Mode Display Checkpoint Check Method and Remedy

Power

●

Heater/Check

●
Power supply voltage
  1. Check that approx. 220 to 240 V AC is supplied at both ends of the power cord connections on the terminal block.
  2. If 220 to 240 V AC is not supplied, check that the earth leakage breaker is turned ON.
  3. If 220 to 240 V AC is not supplied, check that the power cord is connected securely to the terminal block.
View details

Power

●

Heater/Check

●
Power supply voltage on the power circuit board (JT-30P8H)
  1. Check that approx. 220 to 240 V AC is supplied between TAB1 and TAB2 (orange) on the power circuit board (JT-30P8H).
View details